MS005A
Test bench for diagnostics of alternators and starters
The MS005A test bench is designed for fast and accurate diagnostics of alternators and starters for passenger and commercial vehicles. The test bench features high power, which, combined with its electronic control system, enables the diagnostics of a wide range of components. Thanks to the alternator database, the presence of an automatic diagnostic mode, and the ability to use special cables, the time spent on testing components is reduced. A distinctive feature of the MS005A test bench is its capability to diagnose 48V belt-driven starter-generators of mild hybrid vehicles.
Manufacturer:
MSG Equipment
Overview
The MS005A test bench provides a comprehensive assessment of the technical condition of:
- Automotive alternators with a nominal voltage of 12 V and 24 V with any terminal connections.
- 12 V "Stop-Start" system alternators and "I-ELOOP" (Mazda) alternators.
- 48 V belt-driven starter-generators controlled via CAN bus, with the capability to read data from the control unit of this generator type using a diagnostic scanner.
- Automotive starters with a power rating of up to 11 kW and a nominal voltage of 12 V and 24 V, tested in no-load mode.
The test bench displays key parameters in graphical form, providing more information on the unit's technical condition and increasing diagnostic accuracy. 12V/24V alternators and starters can be diagnosed in both manual and automatic modes. A report of the automatic test can then be printed on an external printer or saved to the test bench’s memory. The test bench allows the use of custom automatic test algorithms for alternators.
Features:
- Graphical display of measured parameters.
- Automatic and manual diagnostic modes.
- Capability to use special cables for quick alternator connection (not included).
- Ability to print and save automatic test reports.
- Alternator test parameter settings from the database.
- Convenient unit fixation system.
- Temperature monitoring of the unit with a thermal imaging camera.
- 12" touchscreen for test bench operation.
- Expansion of the range of testable units and the addition of new functions via free software updates.
Supply voltage, V
400
Power consumption, kW
7.5
Software update
yes
Quantity of storage batteries
2 by 12V
Battery model (not included into supply slip)
minimum 45 A·h
Storage battery charging No.1
yes
Storage battery charging No.2
yes
Rated voltage of the diagnosed units, V
12, 24, 48
Load on alternator
12 V - 300 А, 24 V - 150 А, 48 V - 50 А
Load adjustment (0-100%)
smoothly
Drive speed, rpm
from 0 to 3000
Drive speed adjustment
smoothly
Drive type (unit drive)
V-belt drive/Poly V-belt drive
Types of diagnosed alternators 12V
Lamp, SIG, RLO, RVC, C KOREA, P-D, G, C JAPAN, COM (LIN, BSS), VALEO «I-StARS»
Types of diagnosed alternators 24V
Lamp, COM (LIN), PWM, I-ELOOP
Types of diagnosed alternators 48V
CAN
Power of diagnosed starters, kW
up to 11
Control
on the 12" touch screen
Automatic alternator test mode
yes
Alternator database
yes
Saving diagnostic results
yes
Printing of diagnostic results
available on an external printer (not supplied)
Internet connection
Wi-Fi (802.11 a/b/g/ac), Ethernet
Connection of peripheral devices
2 x USB 2.0
Width, m
0,9
Depth, m
0,655
Height, m
1,43
Weight, kg
160
Selecting the direction of rotation of the drive
available
Types of diagnosed voltage regulators
doesn't test voltage regulator
Voltage regulators database
no
Power source
three-phase electrical network
Automatic starter test mode
yes
Video overview
Related videos
Comparison table
Supply voltage, V
400
400
400
230
400
230
Power consumption, kW
7.5
4
5.5
2.2
7.5
1.5
Software update
yes
yes
no
no
yes
yes
Quantity of storage batteries
2 by 12V
2 by 12V
2 by 12V
2 by 12V
2 by 12V
no
Battery model (not included into supply slip)
minimum 45 A·h
capacity from 45 up to 60 A·h and dimensions (L x W x H, mm) not exceeding 207×175×175
capacity from 45 up to 60 A·h
capacity from 45 up to 60 A·h and dimensions (L x W x H, mm) not exceeding 207×175×175
minimum 45 A·h
-
Storage battery charging No.1
yes
yes
yes
yes
yes
-
Storage battery charging No.2
yes
yes
no
no
yes
-
Rated voltage of the diagnosed units, V
12, 24, 48
12, 24
12, 24
12, 24
12, 24
12, 24
Load on alternator
12 V - 300 А, 24 V - 150 А, 48 V - 50 А
12 V - 150 А, 24 V - 75 А
12 V -200 А, 24 V -100 А
12 V - 100 А, 24 V - 50 А
12 V - 300 А, 24 V - 150 А
12 В - 50 А, 24 В - 25 А
Load adjustment (0-100%)
smoothly
smoothly
smoothly
smoothly
smoothly
smoothly
Drive speed, rpm
from 0 to 3000
from 0 to 3000
from 0 to 3000
from 0 to 3000
from 0 to 3000
from 0 to 3000
Drive speed adjustment
smoothly
smoothly
smoothly
smoothly
smoothly
smoothly
Drive type (unit drive)
V-belt drive/Poly V-belt drive
V-belt drive/Poly V-belt drive
V-belt drive/Poly V-belt drive
V-belt drive/Poly V-belt drive
V-belt drive/Poly V-belt drive
V-belt drive/Poly V-belt drive
Types of diagnosed alternators 12V
Lamp, SIG, RLO, RVC, C KOREA, P-D, G, C JAPAN, COM (LIN, BSS), VALEO «I-StARS»
Lamp, SIG, RLO, RVC, C KOREA, P-D, G, C JAPAN, COM (LIN, BSS), VALEO «I-StARS»
Lamp, COM (LIN, BSS), P-D, RLO, C, SIG, F/67
Lamp, COM (LIN, BSS), P-D, RLO, C, SIG, F/67
Lamp, SIG, RLO, RVC, C KOREA, P-D, G, C JAPAN, COM (LIN, BSS), VALEO «I-StARS»
Lamp, SIG, RLO, RVC, C KOREA, P-D, COM (LIN, BSS), C JAPAN, VALEO «I-StARS»
Types of diagnosed alternators 24V
Lamp, COM (LIN), PWM, I-ELOOP
Lamp, COM (LIN), PWM, I-ELOOP
Lamp
Lamp
Lamp, COM (LIN), PWM, I-ELOOP
L/FR, COM (LIN), I-ELOOP
Types of diagnosed alternators 48V
CAN
doesn't test 48 V
doesn't test 48 V
doesn't test 48 V
doesn't test 48 V
doesn't test 48 V
Power of diagnosed starters, kW
up to 11
up to 6
up to 6
up to 4
up to 11
-
Control
on the 12" touch screen
on the 7" touch screen
mechanical controls
mechanical controls
on the 12" touch screen
on the 7" touch screen
Automatic alternator test mode
yes
yes
no
no
yes
yes
Alternator database
yes
yes
no
no
yes
yes
Saving diagnostic results
yes
yes
no
no
yes
no
Printing of diagnostic results
available on an external printer (not supplied)
available on an external printer (not supplied)
no
no
available on an external printer (not supplied)
available via external Bluetooth printer (not supplied)
Internet connection
Wi-Fi (802.11 a/b/g/ac), Ethernet
Wi-Fi (802.11 a/b/g/ac)
no
no
Wi-Fi (802.11 a/b/g/ac), Ethernet
no
Connection of peripheral devices
2 x USB 2.0
2 x USB 2.0; 1 х HDMI
no
no
2 x USB 2.0
1x USB 2.0
Width, m
0,9
0,77
0,55
0,57
0,9
0,57
Depth, m
0,655
0,64
0,45
0,505
0,655
0,49
Height, m
1,43
0,5
1,05
0,45
1,43
0,45
Weight, kg
160
92
111
80
160
41
Selecting the direction of rotation of the drive
available
available
available
available
available
available
Types of diagnosed voltage regulators
doesn't test voltage regulator
Lamp, SIG, RLO, RVC, KOREA, P-D, C JAPAN, COM (LIN, BSS)
Lamp, COM (LIN, BSS), P-D, RLO, C, SIG
Lamp, COM (LIN, BSS), P-D, RLO, C, SIG
doesn't test voltage regulator
doesn't test voltage regulator
Voltage regulators database
no
yes
no
no
no
no
Power source
three-phase electrical network
three-phase electrical network
three-phase electrical network
single-phase electrical network
three-phase electrical network
single-phase electrical network
Automatic starter test mode
yes
yes
no
no
yes
-
Short-circuit protection during voltage regulator test
-
yes
yes
yes
-
-
Training course on diagnostics and repair of starters and alternators
Click the link to learn more about the course
Related Products
MS012
Tester for diagnostics of alternator's voltage regulators
The tester imitates the proper operation of alternator for voltage regulator to enable the accurate evaluation of the voltage regulator performance and the selection of the relevan...
Types of diagnosed voltage regulators
«L/FR», «SIG», «RLO», «RVC», «C KOREA», «P-D», «COM (LIN, BSS)», «C JAPAN»
Voltage regulators database
no
Testing voltage regulators under load
12 V - from 1.8 to 22; 24 V - from 4.1 to 22.
Types of diagnosed voltage regulators
«L/FR», «SIG», «RLO», «RVC», «C KOREA», «P-D», «COM (LIN, BSS)», «C JAPAN»
Voltage regulators database
no
Testing voltage regulators under load
12 V - from 1.8 to 22; 24 V - from 4.1 to 22.
MS014
Tester for diagnostics of stator windings and diode bridges of alternators
The tester checks easily and quickly the stator winding coils and diode bridges revealing all the existing defects.
Voltage regulators database
no
Checking the stator winding for a short circuit to the body
yes
Voltage regulators database
no
Checking the stator winding for a short circuit to the body
yes
MS021
Tester for diagnostics of diode bridges of alternators
The tester MS021 enables the accurate evaluation of the technical condition of alternator diode bridges or diodes – separately. The tester identifies the type and specifications of...
Voltage regulators database
no
Voltage regulators database
no
MS015A
Tester for diagnostics of alternator's voltage regulators
MS015A is a simple and user-friendly device for express diagnostics of 12 and 24V automobile alternators with a controlled or digital voltage regulator directly on the vehicle. The...
Types of diagnosed alternators 12V
COM (LIN, BSS), SIG, RLO, RVC, C KOR., P-D, C JAP.
Types of diagnosed alternators 24V
COM (LIN), PWM
Voltage regulators database
no
Types of diagnosed alternators 12V
COM (LIN, BSS), SIG, RLO, RVC, C KOR., P-D, C JAP.
Types of diagnosed alternators 24V
COM (LIN), PWM
Voltage regulators database
no
Materials about MS005A to download:
Format
Name
Latest update
Ask a Question