MS800
Test bench for starters, alternators, and voltage regulators

The MS800 tester is designed for diagnosing high-voltage nickel-metal hydride (Ni-Mh) and lithium-ion (Li-ion) batteries in hybrid and electric vehicles.
Manufacturer: MSG Equipment
Overview

The MS800 tester is used during the repair of high-voltage batteries in hybrid. The tester can determine the capacity of nickel-metal hydride (Ni-Mh) and lithium-ion (Li-ion) batteries of various types: NMC, NCA, LFP. The battery module diagnostic (balancing) process occurs automatically. The tester incorporates protective systems to prevent battery module damage during diagnostics.

MS800 stores all measured data during the battery module diagnostic (balancing) process in its memory. These data can then be reviewed and analyzed on a PC using the TesterLogReader software, which you can download and use for free.

Capabilities of the tester MS800:

  • Diagnoses high voltage battery modules, determining their capacity.
  • Charges sequentially connected cells of batteries that are unbalanced over time.
  • Prepares the battery for installation on the car by balancing all modules by voltage.
  • Prepares modules for storage, charging them to a certain level.

Features:

  • The tester has 36 independent, galvanically isolated channels for testing (balancing) Ni-Mh or Li-Ion modules.
  • Automatic operating mode.
  • Battery module protection against:
    - overcharging/discharge;
    - overheating;
    - incorrect connection (wrong polarity).
  • Saving diagnostic results.
  • Convenient viewing and analysis of diagnostic results.
  • Management and control of the diagnostic process through a touchscreen.
  • Free software update.
Supply voltage, V
230
Power consumption, kW
3.5
Software update
available
Types of protection
- against polarity reversal; - short-circuit of the connected cable; -from overheating.
Saving diagnostic results
available
Connection of peripheral devices
1 x USB 2.0
Width, m
1,43
Depth, m
0,32
Height, m
0,22
Weight, kg
55
Number of channels for module test
36
Max. channel voltage for Ni-Mh, V
20
Max. channel voltage for Li-Ion, V
4.2
Charge rate, A
from 0.1 tо 4.5
Discharge rate, A
from 0.1 to 5 (limited to 50 W per channel)
Power supply
single-phase electrical network
Video overview
Materials about MS800 to download:
Format
Name
Latest update
15/11/2024